| Foundations and basements |
Spring |
Fall |
Annual |
| Inspect for signs of termites and for wood decay. |
|
|
X |
| Check grading to assure that water will drain away from house; check closeness of trees to foundation for problems from roots. |
|
|
X |
| Check basement and crawl space for dampness and leakage following wet weather. |
|
|
X |
| Check driveways and walks for cracks, settling and soil erosion. |
|
|
X |
| Clean area wells, window sills and storm drains. |
|
|
X |
|
Doors and windows
|
Spring
|
Fall
|
Annual
|
| Check doors, windows and trim for finish failure or rotted wood. |
X |
|
|
| Check for broken glass, damaged screens. Clean screens. |
X |
|
|
| Check glazed openings for loose putty. |
X |
|
|
| Check hardware and lubricate moving parts. |
|
X |
|
| Check weatherstripping for damage and tightness of fit. Check joints and caulk. |
X |
|
|
| Check caulking at doors, windows, and all openings and joints between different materials (such as brick). |
X |
|
|
| Exterior walls |
Spring |
Fall |
Annual |
| Check masonry for cracks and loose joints. |
X |
|
|
| Check painted surfaces for paint failure (pre-1978 homes with cracked or peeling paint on window sills, walls or trim should be referred to Dept. of Health for list of lead inspectors). |
X |
|
|
| Check siding and trim for damage and decay. |
X |
|
|
| Check trim for tightness of fit at joints and caulk. |
X |
X |
|
| Roof |
Spring |
Fall |
Annual |
| Check for damaged or loose shingles, blisters, roofing sponginess, etc. |
X |
|
|
| Check underside of roof where accessible for water stains or dampness. |
X |
|
|
| Check for damage or if paint is needed on gutters, downspouts, hangers, strainers and splash blocks. |
X |
X |
|
| Clean gutter strainers, gutters, downspouts, splash blocks. |
X |
X |
|
| Evaluate roof for future replacement. |
|
|
X |
| Check fascias and soffits for paint failure and decay. Assure that vents are open and properly vented. |
X |
|
|
| Check masonry chimneys for cracks (inside and outside) and for obstructions. |
|
X |
|
| Interior Surfaces |
Spring |
Fall |
Annual |
| Check all painted and natural finished surfaces for dirt, finish failure, and for needed repairs (pre-1978 homes with cracked or peeling paint on window sills, walls or trim should be referred to the Dept. of Health for a list of lead inspectors). |
X |
|
|
| Check all joints in ceramic tile, laminated plastic and similar surfaces. Check caulking around sinks, bathtubs and showers. |
X |
X |
|
| Floors |
Spring |
Fall |
Annual |
| Check for wear, damage, evenness and sponginess. Check particularly where one floor material joins another (e.g., wood to carpet). |
|
|
X |
| Evaluate for replacement or refinish. |
|
|
X |
| Check for handrails on stairs. Make sure they are properly attached. |
|
|
X |
| Electrical system |
Spring |
Fall |
Annual |
| Check areas where wiring is exposed, and replace at first sign of damage. |
X |
X |
|
| If fuses blow or breakers trip frequently, electrician should be contacted to determine cause and make necessary repairs. |
X |
X |
|
| Check condition of cords and extension cords to all appliances. |
X |
X |
|
| Check smoke detectors. |
X |
X |
|
| Heating and cooling systems |
Spring |
Fall |
Annual |
| Have entire system (including gas lines) checked by qualified service person. |
X |
X |
|
| Clean, service or replace filters, humidifiers and dehumidifiers. |
X |
X |
|
| Unvented gas heaters need to have proper ventilation. Have a qualified service person check. |
|
|
X |
| Remove window air conditioners in winter. |
|
X |
|
| Plumbing system |
Spring |
Fall |
Annual |
| Check faucets, hose bibbs, valve stools, sinks and water heater for leakage or corrosion. |
X |
X |
|
| Have service person check septic system. |
|
|
X |
| Check gas lines and make sure no material around water heater is blocking air flow. |
X |
X |
|
| Check to see that water heater vent is not obstructed. |
|
|
X |
| Insulation |
Spring |
Fall |
Annual |
| Ceiling insulation should be an R-30 or approximately 10 inches deep. |
|
|
X |
| Check attic for proper ventilation at soffits and gable to assure air flow. |
|
|
X |
| Wall insulation should be a minimum of R-13 or 3.5 in. |
|
|
X |
| Floor insulation should be a minimum of R-13 or 3.5 in. |
|
|