University of Missouri Extension

WQ308, New July 1993

Flushing Systems for Dairies

Charles D. Fulhage and Donald L. Pfost
Department of Agricultural Engineering

Flushing dairy facilities, such as milking parlors, holding areas and free stall alleys, can replace mechanical scraping or scraping with a tractor and blade. For optimum performance, flushed surfaces are usually sloped at 2 percent to 5 percent to provide adequate flow velocity for good cleaning and transport.

The Missouri State Milk Board requires the milking parlor to be flushed with fresh water, but effluent may be recycled from a lagoon for flushing other areas such as the holding pen, loafing and feeding areas.

Advantages

The following list includes some advantages of flushing dairy facilities, compared to scraping with a tractor and blade.

Disadvantages

This list includes disadvantages of flushing.

Components required

Major components required for a typical flush system include a "water" supply, recycle system, flush tanks, sloped/curbed alleys or areas to flush and a receiving gutter at the lower end of the flushed areas (Figure 1).

Scematic of typical components in a dairy flush system Figure 1
Schematic of typical components in a dairy flush system.
 

Water supply

The usual "water" supply/storage is an anaerobic lagoon. The farm water system may provide for "fresh-water" flushing in the parlor.

Recycle system

Pumps

The recycle pumps are usually centrifugal pumps floated on the surface of the lagoon or placed in a wet well at the lagoon. Pumps are usually sized relatively small to reduce first cost as well as wire sizes and electrical demand. The Missouri approach has been to size the recycle pumps and pipes to fill the flush tanks in about two to four hours. Pumps in the 1 to 5 horsepower range will generally provide the 20 to 100 gallons per minute flow rates typical for dairies. Some systems in the West use extremely large pumps that can supply the instantaneous flow rates required to flush channels/alleys without the use of flush tanks. Systems of this type may require a pump capacity of several thousand gallons per minute.

Pumps for dairy lagoons should have an open or semi-open impeller to reduce clogging with solids. If stringy, fibrous material is present in the lagoon, a chopper pump should be used. Solids-separation equipment ahead of the lagoon reduces clogging and pumping problems.

Pumps commonly used include submersible, centrifugal sewage pumps (also called sewage ejector pumps) and self-priming centrifugal pumps that can be placed above the lagoon level in a wet well or in a hut to prevent freezing.

Submersible sewage pumps are usually suspended about 2 feet below the water surface to minimize pumping surface debris or bottom sludge. The recycle pump should be located on the side opposite the discharge from the flushed facility for recycling the best quality water.

In deciding what type of pump and pumping structure will be used, the ability to do maintenance work on the pump must be considered. For floating, submersible pumps, a system of cables to anchor the pump, or floating dock, is needed. For wet-well type pumps, a hoist of some type is needed to lift the pump out of the wet-well for servicing.

Pipes

Polyethylene or PVC pipe is recommended for recycling lagoon water. Fewer crystallization problems seem to occur with plastic than with metal components. Curves with flexible plastic pipe for turning corners is preferable to using 90-degree elbows. Typical pipe diameters range from 2 to 4 inches.

Flush gutters/alleys

Flush gutters/alleys with 2 to 5 percent slopes and 10-inch high curbs are typical. Experience has shown that providing a 5 feet per second flow velocity at a 3-inch depth for at least 10 seconds will provide acceptable cleaning in most cases. A 3 percent slope on the flushed area will provide these conditions with the least water volume and discharge rate requirements. Slopes flatter, or steeper, may require more water volume and higher discharge rates. For the optimum 3 percent slope, flush volumes are about 100 gallons per foot of width of the area being flushed. This volume should be increased for gutters longer than 150 feet. Equal in importance to flush volume is the rate at which the flush tank or valve discharges the flush water into the flush gutter. Adequate flush volume will not provide cleaning if that volume is not discharged fast enough.

Flush tanks and valves should be designed to discharge the required flush volume in about 10 seconds. Gutters longer than 150 feet may require a longer discharge time to maintain an adequate flush wave in the gutter.

Flush tanks and valves

Flush tank types include tip/rollover tanks, siphon tanks and cylindrical "water-tower" tanks (typically 20 to 25 feet tall to provide pressure and storage volume). Pipeline/valve systems typically use tall water towers with large pipes (12-inch diameter typical) and fast-opening valves (butterfly, pneumatic, etc.) to release water into the flush gutter.

Receiving gutters

Receiving gutters (channels) collect the flush water/manure at the end of the flushed surface (alley, holding area, etc.). The open-channel receiving gutter may transport the flush water to the anaerobic lagoon in lieu of a pipe-type conduit. Gutters should be designed with capacity to receive and transport the design flow at sufficient velocity to prevent settling (deposition). Receiving gutters should have at least 2 percent bottom slope, 1-foot minimum depth and 1.5-foot minimum width.

Building site requirements

To achieve an economical flush system, a natural ground slope of 2 to 5 percent in the direction of flow (from the upper end of the flushed area (gutter/alley, etc.) to the lagoon is desired. This allows facilities to be built on the desired slope for flushing with a minimum of earth moving. Buildings can have a roof-line on the same slope as the foundation.

Adequate slope from the flushed facilities to the lagoon eliminates any need for pumping waste to the lagoon. The site must be suitable for construction of a lagoon according to the state regulator's requirements, and it must have sufficient clay in the soil to provide a watertight seal for the lagoon.

 